The LabelWriter SE450 printer has a Printer Configuration Menu built into the firmware. Through this menu, flash memory settings such as baud rate and feed distance can be changed. Flash memory settings remain in effect even after power has been removed from the printer.
The Printer Configuration Menu is accessible by using any terminal communications (modem) program (such as, Hyperterminal in Windows) and communicating with the printer through an RS-232 serial port. The communications software MUST be configured to operate as follows:
9600 baud, no parity, 8 data bits, and 1 stop bit
To access the Printer Configuration menu
Press <Enter> until the menu appears.
Dymo LabelWriter SE450 Firmware Version 1765303v0G Printer Configuration Menu |
Press ? for help.
You should see the following on your screen:
-? B? Display Baud Rate B0 Set 1200 Baud B1 Set 2400 Baud B2 Set 4800 Baud B3 Set 9600 Baud B4 Set 14,400 Baud B5 Set 19,200 Baud B6 Set 28,800 Baud B7 Set 38,400 Baud B8 Set 57,600 Baud B9 Set 115,200 Baud F? Display Default Feed Length Fnnnn Set default feed length X? Display XON/XOFF inhibit status X0 Send XON/XOFF X1 Inhibit XON/XOFF C? Display Caret (^) Status C0 Disable Caret Command C1 Enable Caret Command
- |
The next time you connect power to the printer the changes you made will be in effect.